Patient Monitors YR02170 // YR02171 // YR02172

Manufacturer: Kalstein

Description

The Patient Monitors YR02170 // YR02171 // YR02172 are state-of-the-art devices designed to enhance patient care through advanced monitoring capabilities. These monitors offer a multi-channel display and a big font interface for easy readability. Equipped with features like ST and arrhythmia analysis, drug dose calculation, and an OxyCRG dynamic view display, they provide comprehensive diagnostic support. Safety alarms, including respiration monitoring with apnea alerts and NIBP overpressure protection, ensure patient safety. Whether using a wired or wireless network, these monitors are versatile and reliable, ready to meet the demands of any clinical setting.

Market Price

The market price for patient monitors like the YR02170 // YR02171 // YR02172 generally falls between 900 USD to 1700 USD. This range reflects the advanced capabilities and high quality of the product. Given its robust features and technical specifications, investing in this equipment is worthwhile for healthcare facilities looking to enhance patient monitoring capabilities.

Frequently Asked Questions

Q: Can these monitors be used for pediatric patients?

A: Yes, these monitors are suitable for both adult and pediatric patients, accommodating a wide range of heart rate and respiration measurements.

Q: Do the monitors support wireless connectivity?

A: Yes, the monitors support both wired and wireless network connections, allowing for flexible integration into existing systems.

Advantages and Disadvantages

Advantages: Advanced monitoring features including arrhythmia analysis, high-resolution displays, and adaptable connectivity options.

Disadvantages: May require specific training for optimal use, and upfront costs are higher due to the advanced technology.

Product Use in the Field

In practical scenarios, the Patient Monitors YR02170 // YR02171 // YR02172 are indispensable tools in hospitals and clinics, providing critical data that informs treatment decisions in real-time. Their robust alarm systems alert medical staff to potential issues, enabling swift intervention and enhancing patient outcomes.

Recommendations

For optimal use, it’s recommended to ensure regular maintenance and calibration of the monitors to maintain accuracy. Staff should be trained thoroughly to take full advantage of the monitors’ features. Regular software updates should be implemented to keep the systems running smoothly.

Features

  • Multi-channel display
  • Big font interface
  • ST and arrhythmia analysis
  • Drug dose calculation and titration table
  • OxyCRG dynamic view display
  • Respiration monitoring with apnea alarms
  • Alarm review, arrhythmia review
  • NIBP overpressure protection
  • Plug-in rechargeable battery, AC/DC available
  • Supporting wire or wireless network

Technical Specifications

Model YR02170 YR02171 YR02172
ECG
Lead mode 5 Leads(RA,LA,LL,RL,V)
Connection method I, II, III,AVR,AVL,AVF,V
Lead Mode 3 Leads (RA,LA,LL)
Connection method I, II,III
Waveform 1ch
Gain x250, x500, x1000, x2000
HR Range Adult: 15~300bpm
Neo/Ped 15~350bpm
Accuracy ±1% or ±1bpm
Resolution 1bpm
Sensitivity >200(uVp-p)
Differential input impedance ≥5MΩ
ST segment Monitoring Range
Measure Range -2.0~+2.0mV
Measure Accuracy -0.8mV~+0.8mV
Heart Rate
Measuring range 0~350bpm 20~300bpm
Accuracy ±1bpm
Resolution 1bpm
Sensitivity >200UVp-p
Respiration
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5MΩ
Measuring Impedance Range 0.3~3.0 MΩ
Base line Impedance Range 200~4000Ω
Bandwidth 0.1~2.5Hz
Resp. Rate Adult: 2~120BrPM
Neo/Ped 2~150BrPM 0~150BrPM
Resolution 1 BrPM
Accuracy ±2 BrPM
Alarm 10~40S
NIBP
Method Oscillometric
Mode Manual/Auto/STAT
Measuring Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40~240bpm
Alarm Type SYS, DIA, MEAN
Resolution
Pressure 1mmHg
Accuracy Maximum Mean error: 5mmHg
Maximum Standard deviation 8mmHg
SPO2
Display Number of SPO2,waveform of capacity,Pulse
Measuring range 0~100%
Resolution 1%
Accuracy 70~100% (±2%)
Alarm system Audio-video alarm
Pulse rate range 0~300bpm
TEMP
Channel 2
Measuring and Alarm Range 0~50ºC
Resolution 0.1ºC
Accuracy 0.1ºC
Actualization interval about 1 Second.
Average Time Constant <10 Second.

Additional information

Weight N/A
Dimensions N/A
Model

YR02170, YR02171, YR02172

Quote List

Quote List

No products in the list

Product categories

In this section you can select the sector or product of your interest.

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight