Description
The Bedside Monitor YR02173 is a state-of-the-art patient monitoring system designed to provide comprehensive bedside care. It features a versatile 12.1-inch touch screen for easy navigation and visibility. With its advanced functionality, this device supports 5-lead ECG, RESP, single-channel temperature monitoring, COMEN SpO2, NIBP, and heart rate metrics. Additional modules such as Dual-IBP, EtCO2, AG, ICG, C.O., BIS, Nellcor/Masimo SpO2, and a built-in thermal recorder ensure an all-encompassing monitoring solution. Whether on a trolley or wall-mounted, it integrates seamlessly into varied healthcare settings, making it an essential tool for clinicians seeking accurate and real-time patient data.
Market Price
When considering investing in a bedside monitor, it is crucial to understand the market landscape. The average market price for monitors with similar features as the Bedside Monitor YR02173 ranges from $2000 to $2800 USD. The investment reflects the high-end components and reliable technology embedded in this vital healthcare instrument.
Frequently Asked Questions
What is included with the Bedside Monitor YR02173? The product comes with the main unit, ECG cables, and necessary accessories for all functions such as temperature probes and blood pressure cuffs.
Is the monitor portable? Yes, the Bedside Monitor YR02173 features options for trolley use or wall mounting, providing flexibility based on clinical needs.
Pros and Cons
One of the standout advantages of the Bedside Monitor YR02173 is its comprehensive monitoring capabilities, making it a versatile addition to any medical facility. Its precise data measurement is complemented by its user-friendly interface. However, depending on the healthcare facility, the initial investment could be a consideration, though the long-term benefits and operational efficiencies often offset this.
Field Use
In practical settings, the Bedside Monitor YR02173 is frequently used in hospital wards, acute care environments, and during patient transport. Its accurate monitoring delivers essential information that aids healthcare providers in making timely and informed decisions, enhancing patient care and outcomes.
Recommendations
To maintain optimal performance of the Bedside Monitor YR02173, routine calibration and cleaning according to the manufacturer’s guidelines are recommended. Making use of Kalstein Plus’s automated quotation platform will ensure that you receive timely service updates and can easily request additional features or replacements when necessary. Contact Kalstein Plus today and explore how the YR02173 can transform patient monitoring in your facility.
Features
- 12.1 inch touch screen
- 5-lead ECG, RESP, Temp (Single Channel), COMEN SpO2, NIBP, HR
- Dual-IBP, EtCO2, AG, ICG, C.O., BIS, Nellcor/Masimo SpO2, 3/12-lead ECG, Thermal Recorder, Dual-Temp, Suntech NIBP, Trolley, Wall mount
Technical Specifications
Model | YR02173 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | 1.25, 2.5, 5.0, 10, 20, 40mm/mV, Auto. | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 15~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 60~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | About 1 Second. | |
Average Time Constant | <10 Second. |