Spectrocolorimeter YR05517

The Spectrocolorimeter YR05516 - YR05517 represents cutting-edge innovation in color measurement technology, offering superior precision and reliability. This portable device is designed to ensure accurate relative ΔE and the long-term precision of absolute values for L, A, and B, allowing for international and national standard measurements at any time and place. With a built-in silicon photodiode array and a double-row sensor comprised of 24 groups, users can control color differences with ease, demonstrating unmatched speed and convenience. The spectrocolorimeter is suitable for a wide array of industries, including plastics, electronics, paint and ink, textiles, ceramics, and printing, ensuring accurate production color differences and quality control.
This page provides an overview of the Spectrocolorimeter YR05517, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in Netherlands, with selection criteria adapted to local purchasing, installation and support conditions.
Key factors to consider

Before selecting the Spectrocolorimeter YR05517, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
Its use is oriented to laboratory routines that require observation, control and operational continuity.
For the market in Netherlands, evaluation should consider local context such as agro-tech, biotech, EU CE marking and match the product to the real workload of the laboratory.
Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In Netherlands, budget comparison should include CE references, 230V/50Hz power conditions, accessories, logistics and after-sales support.
Value for money

Advantages: This spectrocolorimeter boasts a high level of precision, ease of use, and a broad range of applications. It is portable and designed for durability with a long battery life, supporting thousands of measurements on a single charge. Disadvantages: The initial cost may be prohibitive for some smaller operations, and users new to advanced spectrocolorimeter technology may face a learning curve.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

For optimal performance, follow all calibration instructions and regularly update the device’s software. Store it in environments within recommended temperature and humidity levels to prolong its lifespan and maintain its measurement accuracy.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to Netherlands helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Spectrocolorimeter YR05517

Spectrocolorimeter YR05517
Características del producto
- Φ Medición de 8 mm de diámetro, ángulo de 10 °, el observador puede cumplir con la mayoría de los requisitos de los clientes de la industria;
- Combinación de fuente de luz LED de espectro completo, rejilla plana y pantalla táctil capacitiva de color verdadero, con un punto de partida alto;
- Matriz de fotodiodos de silicio (24 grupos en columnas dobles), precisión de visualización 0,1, buena repetibilidad;
- La vida útil de la fuente de luz es de más de 3 millones de mediciones en 5 años, y la batería de litio toma 6000 mediciones en 8 horas, que se puede recargar repetidamente y tiene una batería de larga duración;
- Búsqueda, análisis y comparación de datos rápidos con 500 muestras de almacenamiento de datos y 10,000 muestras.
Especificaciones Técnicas
| Model | YR05516 | YR05517 (current) |
| optical geometry | D/8 (diffuse illumination, | D/8 (diffuse illumination, |
| 8-degree viewing angle) | 8-degree viewing angle) | |
| SCI/SCE Mode | SCI/SCE Mode | |
| Complies with CIE No.15, GB/T | Complies with CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 | |
| 3978 GB 2893 GB/T | ||
| 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | ||
| Feature | double apertures, more adaptability; Used for precise | single apertures, more adaptability; Used for precise color measurement and quality control in plastic electronics, paint and ink, printing and dyeing of textiles and garments, printing, ceramics, and other industries. |
| color measurement and quality control in plastic electronics, | ||
| paint and ink, printing and dyeing of textiles and garments, printing, | ||
| ceramics, and other industries | ||
| Integrating sphere size | Φ40mm | Φ40mm |
| Light source | Combined full spectrum LED light source, UV light source | Combined full spectrum LED light source, UV light source |
| Spectrophotometric mode | flat grating | flat grating |
| sensor | Silicon photodiode array (double row 32 groups) | Silicon photodiode array (double row 32 groups) |
| Wavelength range | 400~700nm | 400~700nm |
| Wavelength interval | 10nm | 10nm |
| Half-bandwidth | 10nm | 10nm |
| Measured reflectance range | Long: 0~120; reflectivity: 0 ~ 200% | Long: 0~120; reflectivity: 0 ~ 200% |
| Measurement aperture | Double apertures: MAV: Φ8 mm/Φ10 mm; SAV: Φ4 mm/Φ5 mm | Single apertures: Φ8 mm/Φ10 mm |
| Specular component | SCI/SCE | SCI/SCE |
| Color space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, βxy, DIN Lab9, DIN | CIE Lab, XYZ, Yxy, LCh, s-RGB, βxy, Munsell (C/2) |
| Lab99 Munsell(C/2) | ||
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*00, DINΔE99 | ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99 |
| Other colorimetric index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
| YI(ASTM D1925,ASTM 313), | YI(ASTM D1925,ASTM 313), | |
| Metamerism Index MI, | Metamerism Index MI, | |
| Staining fastness, color fastness, color intensity, | Staining resistance, color fastness, color intensity, opacity, color card search | |
| Opacity, color card search | ||
| Observer angle | 2°/10° | 2°/10° |
| Illuminant | D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), | D65,A,C,D50,F2(CWF), F7(DLF),F10 |
| F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83/U30) | (TPL5),F11(TL84),F12 (TL83/U30) | |
| Displayed data | Spectrogram/Values, Samples Chromaticity values, color difference Values/Graph, PASS/FAIL Result, Color Simulation, color compensation | Spectrogram/Values, Samples Chromaticity values, color difference values/graph, PASS/FAIL result, color simulation, color compensation |
| Displayed accuracy | 0.01 | 0.01 |
| Measuring time | About 1.5 s (SCI and SCE measurement about 3.2 s) | About 1.5 s (SCI and SCE measurement about 3.2 s) |
| Repeatability | Chromaticity value: MAV/SCI, within ΔE*ab 0.05 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration) | Chromaticity value: MAV/SCI, within ΔE*ab 0.06 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration) |
| Instrument error | MAV/SCI, Within ΔE*ab 0.3 | MAV/SCI, Within ΔE*ab 0.3 |
| (Average of 12 BCRA Series II color tiles) | (Average of 12 BCRA Series II color tiles) | |
| Measurement mode | Single measurement, average Measurement (2-99 times) | Single measurement, average measurement (2-99 times) |
| Location method | Camera location, stabilizer cross position | Camera location, stabilizer cross position |
| Dimension | L*W*H=81X71X214mm | L*W*H=81X71X214mm |
| Weight | About 460g | About 460g |
| Battery | Lithium-ion battery, 6000 measurements within 8 | Lithium-ion battery, 6000 measurements in 8 hours |
| hours | ||
| Illuminant lifespan | 5 years, over 3 million times | 5 years, over 3 million times measurements |
| measurements | ||
| Monitor | 3.5-inch color TFT LCD, capacitive touch S | 3.5-inch color TFT LCD, capacitive touch screen |
| screen | ||
| Data port | USBBluetooth 5.0 | USB |
| Data storage | Standard 1000 pieces, sample 30000 PC (One | 1000 standard units, 20000 sample units (one data may include SCI/SCE) |
| data may include SCI/SCE) | ||
| Language | simplified Chinese, English, traditional Chinese | simplified Chinese, English, traditional Chinese |
| Operating environment | 0~40℃, 0~85%RH (no condensation), Altitude | 0~40℃, 0~85%RH (no condensation), Altitude < 2000m |
| < 2000m | ||
| Storage environment | -20~50℃, 0~85%HR (no condensation) | -20~50℃, 0~85%HR (no condensation) |
| Standard accessory | Power adapter, USB cable, user manual, SQCX software (download from office website), white and black calibration cavity, protective cover, wrist strap, 8 mm flat aperture, 8 mm tip aperture, 4 mm flat aperture, 4 mm tip aperture | Power adapter, USB cable, user manual, SQCX software (download from office website), white and black calibration cavity, protective cover, wrist strap, 8 mm flat aperture, 8 mm tip aperture |
| Optional accessory | USB micro printer, dust test box, Bluetooth micro printer | USB micro printer, dust test box, |
| notes | Technical parameters are for reference only, subject to actual product sale | Technical parameters are for reference only, subject to actual product sale |
Products related to model YR05517

High cost-effective portable colorimeter YR05514
Ver producto
High cost-effective Portable Colorimeter YR05515
Ver producto
Spectrocolorimeter YR05518 - YR05519
Ver producto
Precision Colorimeter YR05506 // YR05508
Ver producto
Precision Colorimeter YR05509
Ver producto
Precision Colorimeter YR05510
Ver producto
Precision Colorimeter YR05511
Ver producto
Precision Colorimeter YR05512
Ver productoFrequently Asked Questions about the Spectrocolorimeter YR05517
What industries can benefit from using the Spectrocolorimeter YR05516 - YR05517?
Industries such as plastics, electronics, textiles, ceramics, and printing can greatly improve their color measurement accuracy and efficiency by using this device.
Does the device require a computer or additional software connection for operation?
No, it operates autonomously without the need for a computer or software, making color difference measurements quick and straightforward.
How do I choose the right spectrocolorimeter yr05517 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.