Description
- 7” capacitive LCD color touch screen, fully automatic controlled, easy to operate on.
- Lifting type door, which is more convenient to place and fetch the objects from the autoclave.
- Dynamically showed the temperature, pressure, time, vacuum rate, drying, alarm, water level, and the full cycle.
- The whole procedure from water inlet, pulse vacuum, heating, sterilizing, water outlet, exhausting to vacuum drying, which are all automatically by one-key operation.
- Intellectualize vacuum drying system to guarantee the residual humidity of instrument less than 0.2% .
- The vacuum rate can reach -0.081Mpa, it fits various instruments, including packed, unpacked, dressings, solid, A, B type hollow whether multi-apertures or inset pipes.
- With 7 cycles: Instrument, Textile, Rubber, Liquid, User-defined, vacuum leakage test, BOWIE & DICK test.
- Equipped with the PT/TT testing connector, easy to run the testing.
- Equipped with Germany SARTORIUS Sterile ventilation filter MIDISART 2000 0.2 um, which ensure the air is sterile, prevent the contamination.
- Multiple pulse vacuum drying after sterilizing, ensure the nice sterilizing.
- Adopted independent steam generator, with high heating efficiency.
- Steam-water inner circulation system: No steam discharge and the environment for sterilizing will be clean and dry.
- Automatically shut off with beep reminding after sterilization.
- Internal material: Stainless steel 304, External material: Stainless steel 304 and electrostatic powder coated stainless steel.
- Equipped with a printer.
- Accessories: Drainage hoses, drain(exhaust) bucket, stainless steel baskets.
Safety Protection Device
- Heater protection
- Anti-dry heating
- Safety interlock door: The program can’t start up when the door is unlocked under normal condition. Door is locked and the door can’t open when pressure in chamber.
- Over-temperature protection: Adapt PT100 with accuracy class A for temperature control in chamber, collect temperature data in real-time, protect and alarm when temperature higher than default value.
- Over-pressure protection: The relief valve starts to release pressure automatically when the pressure in chamber and steam generator exceed the default value.
- Automatic release safety valve.
- Over current protect.
- Electric safety protective device: Fuse protects control units when short circuit or overload occurs.
- Overheating protection device: High temperature deviation in chamber actuates protective device cuts off the heating source immediately.
- Vacuum pump overload: The vacuum pump stops and alarms once its motor is overload or blocked when vacuum pump running.
Technical Specifications
Model | YR05688 | YR05689 | YR05690 | YR05691 |
Max. Working pressure | 0.23Mpa | |||
Working pressure | 0.22Mpa | |||
Working temperature range | 105 – 134℃ | |||
Vacuum rate | -0.081Mpa | |||
Accuracy of temperature display | 0.1℃ | |||
Sterilization time | 0 – 99 min | |||
Drying time | 0 – 99 min | |||
Heat average | ≤±1℃ | |||
Type | Vertical Pulsating Vacuum Autoclave | |||
Class | Class B | |||
Control | Microprocessor | |||
Door | Automatic lifting door | |||
Display | LCD color touch screen display | |||
Drying system | Vacuum drying | |||
Steam generator | Separate steam generator | |||
Vacuum pump | Yes | |||
Sterilization program | Liquid, Instrument, Textile, Rubber, User-defined, Vacuum leakage test, B & D test | |||
Water tank | Yes | |||
Printer | Yes | |||
Sterilization box | 2 PCS | |||
Language | English | |||
Voltage | 220V, 50Hz, single-phase | |||
Chamber Size(mm) | 60L / Ø396×490 | 80L / Ø396×650 | 100L / Ø480×560 | 120L / Ø480×660 |
Outer Size(mm) | 686×556×913 | 686×556×1035 | 840×600×970 | 840×600×1060 |
Packing Size(mm) | 786×656×1013 | 786×656×1135 | 940×610×1000 | 940×610×1075 |
G.W. / N.W. | 210/180 kg | 230/200 kg | 300/270 kg | 325/ 295 kg |
Power | 5.4 KW | 5.4 KW | 6.0 KW | 6.0 KW |