Pantalla multicanal Interfaz de fuente grande Análisis ST y de arritmias Cálculo de dosis de fármacos y tabla de titulación Visualización dinámica OxyCRG Monitorización de la respiración con alarmas de apnea Revisión de alarmas, revisión de arritmias Protección contra sobrepresión PNI Batería recargable enchufable, CA/CC disponible. Soporte de red cableada o inalámbrica.

This page provides an overview of the Patient monitor YR02171, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.

This Kalstein model is available for laboratories in Netherlands, with selection criteria adapted to local purchasing, installation and support conditions.

Ver más

Key factors to consider

Key factors to consider

Before selecting the Patient monitor YR02171, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.

Its use is oriented to laboratory routines that require observation, control and operational continuity.

For the market in Netherlands, evaluation should consider local context such as agro-tech, biotech, EU CE marking and match the product to the real workload of the laboratory.

Market price range

Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.

The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.

In Netherlands, budget comparison should include CE references, 230V/50Hz power conditions, accessories, logistics and after-sales support.

Value for money

Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.

Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.

Advantages and disadvantages

Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.

Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.

Expected lifespan based on use and maintenance

Expected lifespan based on use and maintenance

Model YR02170 YR02171 YR02172 ECG Lead mode 5 Leads (RA,LA,LL,RL,V) Connection method I, II, III,AVR,AVL,AVF,V Lead mode 3 Leads (RA,LA,LL) Connection method I, II,III Waveform 1 channel Gain x250, x500, x1000, x2000 HR Range Adult: 15~300 bpm Neo/Ped 15~350 bpm Accuracy ±1% or ±1 bpm Resolution 1 bpm Sensitivity >200(uVp-p) Differential input impedance ≥5MΩ ST segment Monitoring Range Measure Range -2.0~+2.0mV Measure Accuracy -0.8mV~+0.8mV Heart Rate Measuring range 0~350 bpm 20~300 bpm Accuracy ±1 bpm Resolution 1 bpm Sensitivity >200UVp-p Respiration Method Impedance between R-F(RA-LL) Differential Input Impedance >2.5MΩ Measuring Impedance Range 0.3~3.0 MΩ Base line Impedance Range 200~4000Ω Bandwidth 0.1~2.5Hz Resp.

Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.

Support and spare-parts availability oriented to Netherlands helps preserve service continuity and plan preventive maintenance without extended downtime.

Specifications table for the Patient monitor YR02171

Patient monitor YR02171

Patient monitor YR02171

  • Pantalla multicanal
  • Interfaz de fuente grande
  • Análisis ST y de arritmias
  • Cálculo de dosis de fármacos y tabla de titulación
  • Visualización dinámica OxyCRG
  • Monitorización de la respiración con alarmas de apnea
  • Revisión de alarmas, revisión de arritmias
  • Protección contra sobrepresión PNI
  • Batería recargable enchufable, CA/CC disponible.
  • Soporte de red cableada o inalámbrica.
ModelYR02170YR02171YR02172
ECG
Lead mode5 Leads (RA,LA,LL,RL,V)
Connection methodI, II, III,AVR,AVL,AVF,V
Lead mode3 Leads (RA,LA,LL)
Connection methodI, II,III
Waveform1 channel
Gainx250, x500, x1000, x2000
HR RangeAdult: 15~300 bpm
Neo/Ped15~350 bpm
Accuracy±1% or ±1 bpm
Resolution1 bpm
Sensitivity>200(uVp-p)
Differential input impedance≥5MΩ
ST segment Monitoring Range
Measure Range-2.0~+2.0mV
Measure Accuracy-0.8mV~+0.8mV
Heart Rate
Measuring range0~350 bpm20~300 bpm
Accuracy±1 bpm
Resolution1 bpm
Sensitivity>200UVp-p
Respiration
MethodImpedance between R-F(RA-LL)
Differential Input Impedance>2.5MΩ
Measuring Impedance Range0.3~3.0 MΩ
Base line Impedance Range200~4000Ω
Bandwidth0.1~2.5Hz
Resp. RateAdult: 2~120 rpm
Neo/Ped2~150 rpm0~150 rpm
Resolution1 rpm
Accuracy±2 rpm
Alarm10~40 seconds
NIBP
MethodOscillometric
ModeManual/Automatic/STAT
Measuring Interval in AUTO Mode1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 (Min)
Measuring Period in STAT Mode5 Min
Pulse Rate Range40~240 bpm
Alarm TypeSYS, DIA, MEAN
Resolution
PressureView product

Frequently Asked Questions about the Patient monitor YR02171

How do I choose the right patient monitor yr02171 for my laboratory?

Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.

What should I review before requesting a quotation?

Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.

Does Kalstein provide guidance for this type of equipment?

Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.

What maintenance helps extend the equipment lifespan?