Kalstein

Nachtkastje Monitor YR02173

Nachtkastje Monitor YR02173

Pantalla táctil de 12,1 ECG de 5 derivaciones, PRAE, Temp (un canal), COMEN SpO2, PNI, FC Dual-IBP, EtCO2, AG, ICG, C.O., BIS, Nellcor/Masimo SpO2, ECG de 3/12 derivaciones, Registrador térmico, Dual-Temp, Suntech NIBP, Carro, Montaje en pared

This page provides an overview of the Nachtkastje Monitor YR02173, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.

This Kalstein model is available for laboratories in Netherlands, with selection criteria adapted to local purchasing, installation and support conditions.

Ver más

Belangrijke factoren om te overwegen

Belangrijke factoren om te overwegen

Before selecting the Nachtkastje Monitor YR02173, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.

Its use is oriented to laboratory routines that require observation, control and operational continuity.

For the market in Netherlands, evaluation should consider local context such as agro-tech, biotech, EU CE marking and match the product to the real workload of the laboratorium.

Prijsbereik in de markt

Prijsbereik in de markt

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.

The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.

In Netherlands, budget comparison should include CE references, 230V/50Hz power conditions, accessories, logistics and after-sales support.

Prijs-kwaliteitverhouding

Prijs-kwaliteitverhouding

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.

Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.

Voor- en nadelen

Voor- en nadelen

Its use is oriented to laboratory routines that require observation, control and operational continuity.

Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.

Verwachte levensduur op basis van gebruik en onderhoud

Verwachte levensduur op basis van gebruik en onderhoud

Modelo YR02173 ECG Modo principal 5 conductores (RA,LA,LL,RL,V) Método de conexión I, II, III,AVR,AVL,AVF,V Modo Plomo 3 conductores (RA,LA,LL) Método de conexión I, II,III Forma de onda 1ch Gane 1,25, 2,5, 5,0, 10, 20, 40mm/mV, Auto. Gama HR Adulto: 15~300bpm Neo/Ped 15~350bpm Precisión ±1% o ±1bpm Resolución 1bpm Sensibilidad 200(uVp-p) Impedancia de entrada diferencial ≥5MΩ Rango de monitorización del segmento ST Rango de medida -2,0~+2,0mV Medir la precisión -0,8mV~+0,8mV Frecuencia cardiaca Rango de medición 15~300bpm Precisión ±1bpm Resolución 1bpm Sensibilidad 200UVp-p Respiración Método Impedancia entre R-F(RA-LL) Impedancia de entrada diferencial 2,5MΩ Rango de impedancia de medición 0,3~3,0 MΩ Línea base Rango de impedancia 200~4000Ω Ancho de banda 0,1~2,5Hz Frecuencia…

Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.

Support and spare-parts availability oriented to Netherlands helps preserve service continuity and plan preventive maintenance without extended downtime.

Specificatietabel van de Nachtkastje Monitor YR02173

Nachtkastje Monitor YR02173

Nachtkastje Monitor YR02173

  • Pantalla táctil de 12,1
  • ECG de 5 derivaciones, PRAE, Temp (un canal), COMEN SpO2, PNI, FC
  • Dual-IBP, EtCO2, AG, ICG, C.O., BIS, Nellcor/Masimo SpO2, ECG de 3/12 derivaciones, Registrador térmico, Dual-Temp, Suntech NIBP, Carro, Montaje en pared
ModeloYR02173
ECG
Modo principal5 conductores (RA,LA,LL,RL,V)
Método de conexiónI, II, III,AVR,AVL,AVF,V
Modo Plomo3 conductores (RA,LA,LL)
Método de conexiónI, II,III
Forma de onda1ch
Gane1,25, 2,5, 5,0, 10, 20, 40mm/mV, Auto.
Gama HRAdulto: 15~300bpm
Neo/Ped15~350bpm
Precisión±1% o ±1bpm
Resolución1bpm
Sensibilidad200(uVp-p)
Impedancia de entrada diferencial≥5MΩ
Rango de monitorización del segmento ST
Rango de medida-2,0~+2,0mV
Medir la precisión-0,8mV~+0,8mV
Frecuencia cardiaca
Rango de medición15~300bpm
Precisión±1bpm
Resolución1bpm
Sensibilidad200UVp-p
Respiración
MétodoImpedancia entre R-F(RA-LL)
Impedancia de entrada diferencial2,5MΩ
Rango de impedancia de medición0,3~3,0 MΩ
Línea base Rango de impedancia200~4000Ω
Ancho de banda0,1~2,5Hz
Frecuencia respiratoriaAdulto: 2~120BrPM
Neo/Ped0~150BrPM
Resolución1 BrPM
Precisión±2 BrPM
Alarma10~40S
NIBPMétodoOscilométrico
ModoManual/Auto/STAT
Intervalo de medición en modo AUTO1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min)
Periodo de medición en modo STAT5 minutos
Frecuencia de pulso40~240bpm
Tipo de alarmaSYS, DIA, MEAN
Resolución
Presión1mmHg
PrecisiónError medio máximo: 5mmHg
Máximo Desviación típica8mmHg
SPO2
MostrarNúmero de SPO2,forma de onda de capacidad,Pulso
Rango de medición0~100%
Resolución1%
Precisión60~100% (±2%)
Sistema de alarmaAlarma audio-vídeo
Frecuencia de pulso0~300bpm
TEMP
Canal2
Rango de medición y alarma0~50ºC
Resolución0,1ºC
Precisión0,1ºC
Intervalo de actualizaciónAlrededor de 1 segundo.
Constante de tiempo media10 segundos.
 
Product bekijken

Veelgestelde vragen over de Nachtkastje Monitor YR02173

How do I choose the right nachtkastje monitor yr02173 for my laboratorium?

Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.

What should I review before requesting a quotation?

Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.

Does Kalstein provide guidance for this type of equipment?

Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.

What maintenance helps extend the equipment lifespan?

Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.

Neem contact op

Neem contact op met Kalstein