Infant Phototherapy Incubator YR02182: A Comprehensive Product Overview
The Infant Phototherapy Incubator YR02182 is a state-of-the-art device designed specifically for the treatment of neonatal jaundice. This innovative product combines an infant incubator and phototherapy unit into one efficient system, ensuring that premature and ill newborns receive the necessary care in a controlled environment. The YR02182 model stands out for its precise temperature and humidity control, making it an essential tool in neonatal intensive care units (NICUs).
Product Description
The YR02182 model features several key functionalities that enhance its performance for treating newborns with jaundice. It is equipped with adjustable light intensity for phototherapy, allowing clinicians to tailor treatment to the specific needs of each infant. Furthermore, the incubator displays critical parameters such as air temperature, skin temperature, and multiple alarms with three priority levels. Notably, the phototherapy duration can be paused, recorded, and accumulated, and it can be preset to turn off automatically once a predetermined treatment duration has been reached.
The LED phototherapy unit has an impressive lifespan of 20,000 hours, ensuring long-term reliability. The silicone mattress within the unit protects the newborn during phototherapy, while the microprocessor-controlled servo-controller guarantees precise and dependable temperature management. Additionally, the humidity system maintains a constant level of relative humidity, which is crucial for the health of vulnerable infants.
Market Price
| Feature | Details |
|---|---|
| Model | YR02182 |
| Brand | Kalstein |
| Category | Infant Phototherapy Incubator |
| Market Price (USD) | $868.00 |
| Weight (Gross) | 92 kg |
| Dimensions | 108 x 64 x 112 cm |
The market price for this high-quality incubator is approximately $868.00. This pricing positions the YR02182 as an accessible option for hospitals and clinics looking to invest in reliable neonatal care equipment.
Frequently Asked Questions
What is the primary purpose of the Infant Phototherapy Incubator YR02182?
The primary purpose of the YR02182 is to provide a controlled environment for newborns requiring treatment for jaundice through phototherapy, while also maintaining their body temperature and humidity levels.
How does the phototherapy function work?
The phototherapy function of the YR02182 provides adjustable light intensity, allowing healthcare providers to treat jaundice effectively by breaking down bilirubin in the infant's blood. The duration of exposure can also be managed and recorded.
Is the incubator easy to clean?
Yes, the YR02182 features a removable water drawer for easy cleaning and disinfection, ensuring the unit can be maintained in a hygienic condition.
What safety features does the YR02182 include?
The YR02182 includes various safety features such as audible and visual alarms for multiple failures, an automatic shut-off for temperature control, and a self-checking function for affirmative safety assurance.
Can the incubator be adjusted for different working heights?
Yes, the YR02182 has an adjustable working height, which allows healthcare professionals to customize the height of the incubator for their convenience during patient care.
What are the additional accessories available for the YR02182?
Optional accessories for the YR02182 include a side cabinet, front and back doors, humidity monitoring and control units, double-walled bell, and adjustable vertical height features.
Pros and Cons
Like any medical equipment, the Infant Phototherapy Incubator YR02182 has its advantages and disadvantages that healthcare providers should consider.
Pros
- Combines incubator and phototherapy functions for efficient treatment.
- Adjustable light intensity and duration settings for tailored therapy.
- Built-in safety alarms for enhanced patient monitoring.
- Easy to maintain and clean, ensuring hygiene standards.
- Robust construction with an aluminum structure for stability.
Cons
- May require a significant initial investment.
- Weight may limit mobility for some healthcare facilities.
- Specialized training may be necessary for optimal use.
Field Usage
The YR02182 model is extensively used in NICUs across various hospitals and clinics, especially those focusing on premature births or term infants with jaundice. Its advanced features make it a reliable choice for medical professionals who need to provide critical care to the most vulnerable patients.
Recommendations
For healthcare facilities considering the purchase of an Infant Phototherapy Incubator, it is advisable to evaluate the YR02182 model for its comprehensive features and competitive pricing. Additionally, ensure that staff are trained to operate the unit effectively to maximize patient benefits. Investing in quality equipment like the YR02182 can significantly improve neonatal care outcomes.
Request a quote on Kalstein Plus today to explore your options and bring quality care to your facility.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.