Description
- 7” capacitive LCD color touch screen, fully automatic controlled, easy to operate on.
- Lifting type door, which is more convenient to place and fetch the objects from the autoclave.
- Dynamically showed the temperature, pressure, time, vacuum rate, drying, alarm, water level, and the full cycle.
- The whole procedure from water inlet, pulse vacuum, heating, sterilizing, water outlet, exhausting to vacuum drying, which are all automatically by one-key operation.
- Intellectualize vacuum drying system to guarantee the residual humidity of instrument less than 0.2% .
- The vacuum rate can reach -0.081Mpa, it fits various instruments, including packed, unpacked, dressings, solid, A, B type hollow whether multi-apertures or inset pipes.
- With 7 cycles: Instrument, Textile, Rubber, Liquid, User-defined, vacuum leakage test, BOWIE & DICK test.
- Equipped with the PT/TT testing connector, easy to run the testing.
- Equipped with Germany SARTORIUS Sterile ventilation filter MIDISART 2000 0.2 um, which ensure the air is sterile, prevent the contamination.
- Multiple pulse vacuum drying after sterilizing, ensure the nice sterilizing.
- Adopted independent steam generator, with high heating efficiency.
- Steam-water inner circulation system: No steam discharge and the environment for sterilizing will be clean and dry.
- Automatically shut off with beep reminding after sterilization.
- Internal material: Stainless steel 304, External material: Stainless steel 304 and electrostatic powder coated stainless steel.
- Equipped with a printer.
- Accessories: Drainage hoses, drain(exhaust) bucket, stainless steel baskets.
Safety Protection Device
- Heater protection
- Anti-dry heating
- Safety interlock door: The program can’t start up when the door is unlocked under normal condition. Door is locked and the door can’t open when pressure in chamber.
- Over-temperature protection: Adapt PT100 with accuracy class A for temperature control in chamber, collect temperature data in real-time, protect and alarm when temperature higher than default value.
- Over-pressure protection: The relief valve starts to release pressure automatically when the pressure in chamber and steam generator exceed the default value.
- Automatic release safety valve.
- Over current protect.
- Electric safety protective device: Fuse protects control units when short circuit or overload occurs.
- Overheating protection device: High temperature deviation in chamber actuates protective device cuts off the heating source immediately.
- Vacuum pump overload: The vacuum pump stops and alarms once its motor is overload or blocked when vacuum pump running.
Technical Specifications
Model | YR05793 |
Max. Working pressure | 0.23Mpa |
Working pressure | 0.22Mpa |
Working temperature range | 105 – 134℃ |
Vacuum rate | -0.081Mpa |
Accuracy of temperature display | 0.1℃ |
Sterilization time | 0 – 99 min |
Drying time | 0 – 99 min |
Heat average | ≤±1℃ |
Type | Vertical Pulsating Vacuum Autoclave |
Class | Class B |
Control | Microprocessor |
Door | Automatic lifting door |
Display | LCD color touch screen display |
Drying system | Vacuum drying |
Steam generator | Separate steam generator |
Vacuum pump | Yes |
Sterilization program | Liquid, Instrument, Textile, Rubber, User-defined, Vacuum leakage test, B & D test |
Water tank | Yes |
Printer | Yes |
Sterilization box | 2 PCS |
Language | English |
Voltage | 220V, 50Hz, single-phase |
Chamber Size (mm) | Ø340×490 mm – 40L |
Packing Size (mm) | 786×656×1013 |
G.W. / N.W. | 140 Kg |
Power | 5.4 KW+A12:B27 |