Description
The Benchtop Spectrophotometer YR05476 by Kalstein is an advanced measurement tool engineered for precision color and appearance analysis in various laboratory and industrial scenarios. Equipped with a 7-inch TFT touch screen, it offers a seamless user interface for both experts and novices. Its sophisticated optical design supports reflective d/8 and transmissive d/0 geometries, allowing users to measure color on reflective surfaces and within liquids or translucent/transparent solids. With LED and UV illumination, a dual-array 256-element CMOS sensor, and a concave grating, you can rely on stable, accurate results every time. Additionally, its vast storage capacity of up to 40,000 records empowers rigorous quality management in industries such as plastics, textiles, paints, and cosmetics.
Market Price
The Benchtop Spectrophotometer YR05476 is positioned as a competitively priced solution, generally ranging between $12,500 to $13,000 USD. This cost-effective pricing makes it an ideal choice for businesses that demand dependable precision in color analysis and quality assurance without compromising budget constraints. We invite you to explore a customized quote tailored to your specific needs on the Kalstein Plus platform, where obtaining a quote is quick and straightforward.
Frequently Asked Questions
- Can the YR05476 measure both opaque and translucent samples?
Yes, this spectrophotometer is designed to measure a wide range of materials, including both opaque and translucent substances like liquids and transparent solids. - What is the device’s storage capacity?
The YR05476 can store up to 40,000 measurement records, allowing for detailed analysis and comprehensive tracking of color data. - Is the measurement aperture adjustable?
Indeed, this model offers adjustable apertures with options from φ25.4 mm to 4 mm, enabling precision tailored to specific measurement needs.
Advantages and Disadvantages
One of the most compelling advantages of the YR05476 is its precision in performing color measurements across various color spaces, enhanced by a temperature compensation system. Its ergonomic design supports continuous, fatigue-free use. A consideration to note is the potential need for regular calibration in extremely high-use settings, ensuring it maintains its peak accuracy.
Field Use
The YR05476 is perfectly suited for high-demand sectors like automotive, cosmetics, medical, and food industries where visual appearance and color fidelity are crucial. Its capabilities in both reflectance and transmittance measurements make it an indispensable asset for quality control and product development, optimizing processes to ensure conformity with quality standards.
Recommendations
For optimal performance of the YR05476, regular calibration and maintaining the instrument in a clean, stable environment are advised. Adjusting the measurement aperture to match the sample type and testing conditions is critical to achieving accurate, consistent results. Discover how the YR05476 Benchtop Spectrophotometer can revolutionize your quality control processes by requesting a personalized quote through Kalstein Plus today, ensuring precise and trustworthy measurements in every application.
Features
- 7-inch TFT touch screen for an intuitive user experience
- Supports both reflective and transmissive measurement geometries
- Storage capacity for up to 40,000 records
- Dual-array CMOS sensor for stable results
- Suitable for a range of materials including opaque, translucent, liquids, and solids
- Adjustable measurement apertures for tailored precision
Technical Specifications
| Model | YR05476 |
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| Integrating Sphere Size | Φ154mm |
| Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 10nm |
| Measured Reflectance Range | 0-200% |
| Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
| Transmissive: Φ30mm/Φ25mm; | |
| Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI & SCE / Transmittance: SCI & SCE |
| Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 |
| Color Difference Formula | ΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1), ΔE * 00, DINΔE 99, ΔE (Hunter) |
| Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter) |
| YI (ASTM D1925, ASTM 313) | |
| MI (Metamerism Index) | |
| Staining Fastness, Color Fastness, Color Strength, Opacity | |
| 8° Glossiness, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) | |
| Observer Angle | 2°/10° |
| Illuminant | D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) |
| Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 (When a white calibration plate is measured 30 times at 5-second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) | |
| Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 (When a white calibration plate is measured 30 times at 5-second intervals after white calibration) | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 |
| (Average for 12 BCRA Series II color tiles) | |
| Dimension | L*W*H=370x300x200mm |
| Weight | Approx. 9.6kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB & Bluetooth & Print serial port |
| Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
| Language | Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish) |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber, Transmissive Test Component |
| Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
| Notes: | The specifications are subject to change without notice. |







