Description
The Grating Spectrophotometer YR05493 from Kalstein is an exceptional tool in the realm of precise color analysis, catering to industries ranging from electronics to textiles, plastics, and food. With three versatile measurement apertures (φ8 mm, φ4 mm, and 1×3 mm), this device adapts seamlessly to samples of diverse sizes. The spectrophotometer boasts a 1000-line grating and a 40-group dual silicon photodiode array sensor for stable and precise measurement across the visible spectrum (400 to 700 nm). Its ergonomic design and dual d/8 optical structure facilitate both SCI and SCE measurements, complying with international standards like CIE No.15 and ASTM E1164, making it an ideal choice for both laboratory and production quality control.
Market Price
The market price for the Grating Spectrophotometer YR05493 hovers around $8885 to $9685 USD, varying with configurations and accessories. This investment promises improved precision and efficiency in color control processes. For a tailored quote or automatic estimate, visit the Kalstein Plus platform for a quick and secure purchasing experience.
Frequently Asked Questions
- What industries benefit most from the YR05493?
Ideal for plastics, textiles, ceramics, printing, and especially for fluorescent samples. - Is there PC software included with the device?
Yes, PC-compatible color management software is included, facilitating detailed analysis and comprehensive color quality data management. - What is the storage capacity of the device?
The spectrophotometer can store up to 1,000 standards and 30,000 samples, allowing for meticulous and organized record-keeping.
Advantages and Disadvantages
The YR05493 offers significant advantages such as remarkable precision with a standard deviation of ΔE*ab of just 0.03, adaptability through various apertures, and compatibility with an array of color spaces and light sources. Its USB and Bluetooth 4.2 connectivity ensures swift data transfer. However, it is limited to the visible spectrum (400-700 nm), which might restrict its use in applications requiring a broader wavelength range.
Field Applications
The YR05493 is extensively employed in scenarios demanding high color accuracy, including plastics, textiles, coatings, and ceramics manufacturing. Its capacity to measure in both SCI and SCE modes, combined with various apertures, ensures adaptability to different sample needs, guaranteeing consistent results. It’s instrumental in color verification for signage products and reflective films, making it indispensable in laboratories and production lines.
Recommendations
For optimal YR05493 performance, regular calibration is recommended, and the instrument should be maintained in a clean, dust-free environment. The lithium-ion battery allows up to 6,000 measurements over 8 hours, so regular recharging is encouraged. Visit Kalstein Plus to request a personalized quote or generate a quick estimate, and see how the YR05493 Grating Spectrophotometer can enhance precision and efficiency in your industry’s color control, optimizing each stage of the production process.
Features
- Ergonomic design for easy handling
- Compatibility with multiple color spaces and light sources
- High precision and wide range of applications
- Multiple apertures for adaptable measurement
- Complies with international standards like CIE No.15 and ASTM E1164
- USB and Bluetooth 4.2 connectivity for fast data transfer
Technical Specifications
Model | YR05493 |
Optical Geometry | D/8 (diffused illumination, 8-degree viewing angle) |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source | |
Conforms to CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
Characteristic | 3 measuring apertures for accurate color analysis and transmission in laboratory |
It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. | |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Sensor | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | 3 apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm |
LAV1x3mm: Slightly poor accuracy, can be used for color test | |
Specular Component | SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2)) |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),
ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
YI(ASTM D1925,ASTM 313), | |
Metamerism Index MI, | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
8° Glossiness,555 tone classification | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,
F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating,stabilizer cross position |
Dimension | L*W*H=129X76X217mm |
Weight | Approx 600g |
Battery | Li-ion battery, 6000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth 4.2 |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Language | Simplified Chinese, English, traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture,1x3mm tip aperture |
Optional Accessory | Micro Printer, Powder Test Box, Holding base |
Notes | The specifications are subject to change without notice. |