Description
The ATC Car Refractometers YR05916 // YR05930 are essential tools for accurately measuring the concentration of ethylene glycol and propylene glycol in antifreeze solutions. These refractometers are equipped with an Automatic Temperature Compensation (ATC) feature, ensuring precise readings by automatically adjusting to temperature variations. Constructed with pure aluminum, they are robust, durable, and suitable for various automotive and industrial applications, making them an invaluable asset for professionals in the field.
Market Price Overview
In the current market, refractometers with similar capabilities and quality tend to fall within a price range of approximately 60 USD to 180 USD. This makes the ATC Car Refractometers an attractive option for those seeking cost-effective yet high-performance tools. Although these prices can fluctuate based on availability and demand, the value offered by the ATC models is unmatched.
Frequently Asked Questions
- What is the primary use of the ATC Car Refractometers? The refractometers are primarily used to measure the freezing point and concentration of antifreeze liquids to ensure proper vehicle maintenance.
- Do these refractometers require a power source? No, they utilize ambient light for measurements, so no batteries or external power sources are needed.
- How do I clean and maintain the refractometer? Simply wipe the refractometer with a soft, damp cloth after use to maintain its accuracy and longevity.
Advantages and Disadvantages
One of the main advantages of these refractometers is their ability to deliver precise measurements under various temperature conditions, thanks to the ATC feature. Additionally, they are easy to focus and calibrate, providing users with a seamless experience. However, some users may find that the absence of digital displays can complicate data interpretation, and they require a bit of practice to master their operation fully.
Product Use in the Field
In practical scenarios, the ATC Car Refractometers are used by automotive technicians to ensure that vehicle cooling systems are functioning optimally. By quickly and accurately identifying the composition of antifreeze solutions, technicians can make informed decisions about necessary adjustments or replacements, enhancing vehicle performance and longevity.
Recommendations
For optimal performance, periodically calibrate the refractometer using a standard reference solution to maintain its accuracy. Always store the device in a dry, cool place to prevent damage and ensure its operational longevity. To explore the full potential of these refractometers, you can generate a quote or request more information through our Kalstein Plus platform.
Features
- Robust pure aluminum construction
- Powered by ambient light; no external power source needed
- Easy focusing and calibration process
- Comfortable non-slip rubber cushion
- Automatic Temperature Compensation (ATC) function
- High durability and longevity
Technical Specifications
Model | Description | Measurement Range | Min. Div. | Accuracy | ATC | ATC Temp. | Material |
YR05916 | Car ATC E:-60°C–0°C P:-50°C-0°C B:1.100-1.400sg optical | B:1.000-1.400sg, E:-60℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05917 | Car ATC E:-60°C–0°C P:-50°C-0°C B:1.100-1.400sg optical | B:1.000-1.400sg, E:-60℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05918 | Car ATC E:-60°F-32°F P:-50°F-32°F B:1.15-1.30sg optical | B:1.15-1.30sg, E:-60°F-32°F, P:-50°F-32°F | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05919 | Car ATC E:-60°F-32°F P:-50°F-32°F B:1.15-1.30sg optical | B:1.15-1.30sg, E:-60°F-32°F, P:-50°F-32°F | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05920 | Car ATC E:-50°C-0°C P:-50°C-0°C B:1.15-1.30sg optical | B:1.15-1.30sg, E:-50℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05921 | Car ATC E:-50°C-0°C P:-50°C-0°C B:1.15-1.30sg optical | B:1.15-1.30sg, E:-50℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05922 | Car ATC E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05923 | Car ATC E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05924 | ATC B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C | B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05925 | ATC B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C | B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05926 | ATC E:-70°C-0°C(-90°F-32°F),P:-60°C-0°C(-70°F-32°F)B:1.100-1.400sg | E:-70°C-0°C (-90°F-32°F) P:-60°C-0°C (-70°F-32°F) B:1.100-1.400sg | 5°C (10°F) 5°C (10°F) 0.01sg | ±5°C (10°F) ±5°C (10°F) ±0.01sg | Yes | 0-30°C | Pure aluminium |
YR05927 | ATC E:-70°C-0°C(-90°F-32°F),P:-60°C-0°C(-70°F-32°F)B:1.100-1.400sg | E:-70°C-0°C (-90°F-32°F) P:-60°C-0°C (-70°F-32°F) B:1.100-1.400sg | 5°C (10°F) 5°C (10°F) 0.01sg | ±5°C (10°F) ±5°C (10°F) ±0.01sg | Yes | 0-30°C | Pure aluminium |
YR05928 | ATC Adblue: 30%–35%B:1.100- 1.400sg E:-50°C-0°C P:- 50°C-0°C C:-40°C-0°C optical refractometer | Adblue: 30%–35%B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05929 | ATC Adblue: 30%–35%B:1.100- 1.400sg E:-50°C-0°C P:- 50°C-0°C C:-40°C-0°C optical refractometer | Adblue: 30%–35%B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05930 | RHA-801 ATC 0-40% Urea Concentration AD Blue Optical | 0%-40% Urea Concentration | 0.2%Urea Concentration | ±0.2%Urea Concentration | Yes | 10-30° C | Pure aluminium |